Ground Vibration Testing (GVT)

 

LMS Test.Lab Ground Vibration Testing is a complete solution for performing multiple inputs and multiple outputs modal testing with various excitation techniques in order to get better insight of cirtical and non-critical resonance frequencies in shorter time. LMS Test.Lab Ground Vibration Testing combines LMS Test.Lab MIMO FRF Testing, LMS Test.Lab MIMO Sine Sweep Testing, LMS Test.Lab MIMO Stepped Sine Testing and LMS Test.Lab MIMO Normal Modes Testing, it provides excitation capacities ranging from random excitation, swept sine, stepped sine to normal modes, giving engineers an abundance of open loop and closed loop excitation possibilities.

 

Ground Vibration Testing LR 06.jpgLMS Test.Lab Ground Vibration Testing is a complete solution for performing stepped sine and normal modes testing. Together with LMS Test.Lab MIMO FRF Testing, LMS Test.Lab Structures provides excitation capacities ranging from random excitation and swept sine to stepped sine and normal modes, giving engineers an abundance of open loop and closed loop excitation possibilities.

With the VD8 acquisition card providing differential inputs to eliminate ground loops problem, the LMS SCADAS Lab is a compact system relative to high channel count. Up to 160 channels can be built on one master frame and up to 168 channels on a slave frame. The combination of master and slave frames, connected with optical fiber cables, provides a multi-frame system configuration for more than 400 channels. This reduces the length of the wires and makes the test setup easier.

LMS Test.Lab Ground Vibration Testing has been set up so that channel configuration can be easily carried over from one solution to another. Once the channel setup is defined, all the acquisition applications can share the same configuration; you only have to load the appropriate acquisition tool and fix the corresponding parameters to start the measurements. This significantly speeds up the use of different excitation signals when performing a ground vibration test on an aircraft.

Random excitation

LMS Test.Lab MIMO FRF Testing provides a productive state-of-the-art modal testing solution supporting structural excitation by up to 16 shakers. Random, burst random, sine, burst sine, periodic chirp excitation, pseudo random, periodic random and time replay can be easily defined. Random excitation provides the phase separation technique which gives a first analysis of the structure. Modal analysis can be performed right after the measurements. Most modes can already be selected during a random excitation measurement. As a result, the test duration is reduced by one third.

The LMS Test.Lab MIMO FRF solution provides more information on this topic.

MIMO sine testing

MIMO sine testing provides a multiple input and output swept sine acquisition and a multiple input and output stepped sine acquisition.

By exciting the structure with a sweeping sine over a period longer than one block, LMS Test.Lab MIMO Sine Sweep Testing combines the high sine excitation signal-to-noise ratio with broadband testing measurement speed. During MIMO testing, multiple sine sweeps with different phase conditions between the averages provide correct frequency response functions. Accurate sine extraction results in leakage-free response spectra, while a system identification step prior to the sine sweep helps control excitation levels and further increase the dynamic range of the 24-bit A/D converters. Harmonic distortion spectra and excitation level control following a reference profile provide insights into the structure’s nonlinear behavior.

LMS Test.Lab MIMO Sine Sweep Testing provides more information on this topic.

By exciting the structure with a stepped sine, LMS Test.Lab MIMO Stepped Sine Testing combines the high sine excitation signal-to-noise ratio and front-end controlled input force and provides proper excitation on lightly damped structures. Up to 16 exciters with different types of level control are available. Fixed voltage level on exciters can be used for nonlinearity characterization under open loop conditions. Amplitude and phase control of input forces provide high accuracy in phase control closed loop during the stepping phase by a special MIMO FRF based control algorithm, using singular value decomposition for the FRF matrix inversions. Multiple frequency ranges present fine frequency resolution around resonances where necessary, and coarse resolution elsewhere to save time.

LMS Test.Lab MIMO Stepped Sine Testing provides more information on this topic.

MIMO normal modes testing

LMS Test.Lab MIMO Normal Modes Testing provides a multiple input and output phase appropriation technique.

It is designed to directly measure resonance frequency, damping and modes shape on a structure. The Test.Lab MIMO Normal Modes Testing automatically adjusts the amplitude and phase of the forces injected into the structure to tune a single normal vibration mode. Manual or automatic resonance tracking and force appropriation techniques are available. The frequency and forcing vector must be identified and applied so that the complete structure vibrates only according to the desired mode and that all acceleration responses are in phase quadrature with the input force vector.

LMS Test.Lab MIMO Normal Modes Testing provides more information on this topic.




Features

  • Up to 16 exciters
  • Open and closed loop control
  • Measures transfer functions with random, swept sine, and stepped sine excitation
  • Measures resonance frequency, damping ration and deflection directly with normal mode excitation
  • Supports non-linearity study


Benefits

  • Reduced test time with easily recoverable channel setup for all acquisition applications
  • All applications are built on the same LMS Test.Lab platform
  • Fast and easy data reporting
  • Immediate data validation without switching between applications
  • Reduces test cycles for ground vibration testing
  • Seamless integration with LMS Test.Lab Modal Analysis solutions



    Covering a range of industries, LMS application cases let you discover how LMS solutions help our customers solve their real-life engineering challenges. 

    NASA engineers and researchers rely on LMS technologies in designing and testing advanced spacecraft

    NASA spacecraft modal tests 4Using modal data from LMS Test.Lab, researchers at the Marshall Space Flight Center created hybrid models with LMS Virtual.Lab to determine critical loading on giant rocket nozzles of NASA’s next-generation Ares launch vehicle. As part of its responsibility for many of the modal tests within the U.S. space agency, Marshall’s Structural Dynamics Test Branch also will use LMS Test.Lab for ground vibration tests of the new vehicles. In these and other projects, NASA engineers and researchers rely on LMS technologies in designing and testing advanced spacecraft that will travel the solar system in the coming decades.


    An Integrated Approach to the Dynamic Testing of Aerospace Structures

    Aircraftstructures1.gifOne of the greatest difficulties in designing aircraft structures is that only a very limited number of prototypes are available and then only late in the development process. When prototypes finally become available, it is essential to perform the required testing in as little time as possible. This application note explains how testing teams can get the greatest possible volume of information from every test while preventing errors that would make it necessary to run tests again.






    Images

    Ground Vibration Testing LR 07.jpg Ground Vibration Testing LR 03.jpg Ground Vibration Testing LR 04.jpg
    The solution helps aircraft and spacecraft manufacturers accelerate testing assignments with higher quality data production. Harmonic distortion spectra and excitation level control following a reference profile provide insights into the structure’s nonlinear behavior. LMS Test.Lab MIMO Normal Modes Testing provides a multiple input and output phase appropriation technique.




    Please fill in all required fields (marked with an asterisk).

    First Name *
    Name *
    Function
    Company *
    Country *
    Phone *
    E-mail *
    Please contact me - I have a technical question
    Please contact me for a commercial offer
    Comments *
     


     

    Do you have a technical or commercial question?

    Request your quotation

    LMS TestLab sol Guide.jpg